Recording studios in Madrid
Recording studios in Madrid
PERFORMANCE
Integral has made the acoustic sound design, installation and certification of the studies Sound accordance with the rules AES Reference Document TECHNICAL COUNCIL AESTD1001.1.01-10. It has conducted assembly 3 controls and three call centers in direct collaboration with the customer.
Treatments in controls:
Sound insulation systems is carried out as follows:
1) The acoustic floor has been built with insulating acoustic material Acustilastic-N checkerboard format, combined with a slab of 10cm hormigónde.
2) The insulating ceilings are composed of double layer of cardboard plaster combined with insulating sheet LA10. According to the AI-TC33 Integral Acoustic system.
3) The outer or intermediate peredes have been built with concrete Soundblox acoustic block. The acoustic cladding is made of double plasterboard insulating sheet combined with LA10.
4) Access to the sites through acoustic doors RS3 and VR viewers to allow visibility between call centers and controls.
5) acoustic mufflers Silenbox to ensure isolation of air conditioning and ventilation systems.
Acoustic conditioning systems are mounted as follows:
1) The soil has been treated using coir carpet.
2) The walls have been treated by means of acoustic upholstered Acustiart-P type, developing appropriate measures to meet the restrictive criteria of the AES-TD1001 standard forms.
3) The absorbent roof is built with the system of upholstered Acustiart-P and topped with an acoustic cloud with Acustiart Digital system, which serves as an absorbent part of treatment and indirect lighting.
4) The low frequency control is carried out by resonators systems TR-R92 type and subsequent acoustic diffusion through acoustic diffusers TR-Q2.
Locutorios treatments:
Sound insulation systems is carried out as follows:
1) The acoustic floor has been built with insulating acoustic material Acustilastic-N checkerboard format, combined with a slab of 10cm concrete.
2) The insulating ceilings are composed of double layer of cardboard plaster combined with insulating sheet LA10. According to the AI-TC33 Integral Acoustic system.
3) The outer or intermediate peredes have been built with concrete Soundblox acoustic block. The acoustic cladding is made of double plasterboard insulating sheet combined with LA10.
4) Access to the sites through acoustic doors RS3 and VR viewers to allow visibility between call centers and controls.
5) acoustic mufflers Silenbox to ensure isolation of air conditioning and ventilation systems.
Acoustic conditioning systems are mounted as follows:
1) The soil has been treated using coir carpet.
2) The walls have been treated by means of acoustic upholstered Acustiart-P type, developing appropriate measures to meet the restrictive criteria of the AES-TD1001 standard forms.
3) The absorbent roof is built to be part of indirect lighting in the room, including pyramidal acoustic panels 600x600mm breeze.
4) The low frequency control is carried out by resonators systems TR-R92 type.
DATA SHEET
Project: Sound Studios in Madrid
Sector: Audiovisual Media. Sound Studios
Work Ref. O01MA500679.
TREATMENTS
- Acustilastic-N floor acoustic insulation.
- acoustic ceiling insulation AI-TC33 insulating sheet LA10.
- or intermediate insulating exterior walls with Soundblox.
- Trasdosados AI-TD33 acoustic insulation with insulating sheet LA10.
- insulating acoustic doors RS3.
- VR acoustic visors.
- Silenbox acoustic mufflers.
- Absorbent mode acoustic treatments upholstered Acustiart-P.
- sound absorption ceiling by acoustic cloud Acustiart Digital.
- Low frequency resonators TR-R92.
- acoustic diffusers TR-Q2.